{"product_id":"hyundai-hgm-400s-molded-case-circuit-breaker","title":"Hyundai hgm 400s molded case circuit breaker","description":"\u003cstyle\u003e\n       table {\n           width: auto;\n           border-collapse: collapse;\n           font-size: 16px;\n       }\n       table, th, td {\n           border: 1px solid black;\n       }\n       th, td {\n           padding: 8px;\n           text-align: left;\n       }\n       th {\n           background-color: #dddddd;\n       }\n   \u003c\/style\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 99.9968%; height: 604.746px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 0.370371px;\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003cth style=\"width: 33.0665%; height: 22.3843px;\"\u003eAttribute\u003c\/th\u003e\n\u003cth style=\"width: 60.997%; height: 22.3843px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7685px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 44.7685px;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 44.7685px;\"\u003eHyundai HGM 400S Molded Case Circuit Breaker 400A 460V 50\/60HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003eHyundai Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eSupplier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003eDintec Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003eHGM 400S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003e400AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7685px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 44.7685px;\"\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 44.7685px;\"\u003e460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7685px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 44.7685px;\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 44.7685px;\"\u003e8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003e50kA at 460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7685px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 44.7685px;\"\u003e\u003cstrong\u003eService Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 44.7685px;\"\u003e100% of Icu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003eCat. A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eItem Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003eHBS403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7685px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 44.7685px;\"\u003e\u003cstrong\u003eItem Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 44.7685px;\"\u003eMolded Case Circuit Breaker, HBS403\/400A (New Model: HGM400S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003eKorea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3843px;\"\u003e\n\u003ctd style=\"width: 33.0665%; height: 22.3843px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.997%; height: 22.3843px;\"\u003e5.250 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHyundai HGM 400S Molded Case Circuit Breaker is a durable 400A circuit breaker intended for use in industrial and commercial power systems. It provides a high breaking capacity of 50kA at 460V, offering high-quality fault current interruption. Its high voltage insulation of 1000V and impulse withstanding voltage of 8kV make it highly safe and reliable. This MCCB is in accordance with IEC 60947-2 standards and is a reliable choice for protection against overloads and short circuits.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0633\/9074\/4727\/files\/20210515_165248_resized_1120x_04e47f8b-4789-4762-a339-14d8bca75495_480x480.webp?v=1777635392\" style=\"margin-bottom: 16px; float: right;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e1. High Breaking Capacity:\u003c\/strong\u003e This breaker has breaking capacity of 50kA @ 460V, hence allowing it to break extremely high fault currents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Service Reliability 100% (Ics=Icu): \u003c\/strong\u003eThis breaker has a service breaking capacity equal to its ultimate breaking capacity; hence, making it reliable in case of many fault situations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Good Protective Functionality: \u003c\/strong\u003eThis breaker possesses thermal\/ magnetic trip units, making it able to provide protection against fault situations such as overcurrent and short circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Good Insulating Capacity: \u003c\/strong\u003eIt is capable of offering excellent insulating ability due to its high insulation voltage (Ui) of 1000V and impulse voltage of 8kV (Uimp)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Compliance to Other Devices: \u003c\/strong\u003eIt is able to comply to standard requirements as per the IEC 60947-2.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Industrial Power Distribution System: \u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eThe devices find widespread use in industries, plants, and heavy industries where there is a need for protection of power distribution network, electric motors, and equipment from overloading and short-circuit problems.\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Commercial Building Electrical Supply System: \u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eIdeal for use in commercial building complexes, shopping centers, and offices that require reliable and steady power supply system protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003e3. Marine \u0026amp; Offshore Environment: \u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eFind efficient use in marine power panels and electrical systems of ships and vessels due to its robust construction and effective protection against faults.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Power Control Panels: \u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eUseful in power control panels as well as power switchgears assembly for protection of electric circuits in automation system.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Solar Energy Systems: \u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eIdeal for use in solar energy systems and battery energy storage systems for protection of power converter, batteries, and distribution circuits.\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Large-Scale Infrastructure Installation: \u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eFind application in large-scale infrastructures such as airports, rail systems, and data centers that need continuous power supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDiscover the \u003ca href=\"https:\/\/aeliyamarine.com\/products\/siemens-6ep1-332-2ba00-sitop-power-4-stabilized-power-supply-unit-dc-24v-3-8a\" title=\"reliable Stabilizing Power unit\"\u003e\u003cstrong\u003ereliable Stabilizing Power unit\u003c\/strong\u003e\u003c\/a\u003e at Aeliya Marine Tech engineered for stable voltage regulation, efficient performance, and long-lasting protection in electronic and automation systems.\u003c\/p\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":47397975785623,"sku":"26344","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0633\/9074\/4727\/files\/20210515_165039_resized.jpg?v=1727279748","url":"https:\/\/aeliyamarine.com\/products\/hyundai-hgm-400s-molded-case-circuit-breaker","provider":"Aeliya Marine","version":"1.0","type":"link"}