{"product_id":"line-insulation-monitor-1210-6041","title":"Line insulation monitor 1210-6041","description":"\u003cstyle\u003e\ntable {\n  border-collapse: collapse;\n  width: auto;\n}\nth, td {\n  border: 1px solid black;\n  padding: 8px;\n  text-align: left;\n}\nth {\n  background-color: #f2f2f2;\n}\n\u003c\/style\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine Insulation Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1210-6041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransformer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFL 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5VA primary, 10VA secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4A primary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEC 10VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61558, IEC 615580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLine Insulation Monitor (Part No: 1210-6041) is a premium monitoring instrument utilized for insulation faults detection within electric systems. With a FL 100 type transformer, it features a primary voltage of 115V and secondary voltage of 12V, which makes it apt for numerous electric configurations. The monitor provides a power rating of 5VA on the primary side and 10VA on the secondary side, with a current rating of 0.4A on the primary. The equipment is designed to run between a frequency of 50-60Hz, and the insulation test voltage has an upper limit of 5000V, which guarantees electrical system safety. Built to function in temperatures up to TA40°C, the Line Insulation Monitor is certified to high levels of safety, such as EN 61558 and IEC 61558.\u003c\/p\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0633\/9074\/4727\/files\/20190930_142610_resized_1120x_80dec583-7b47-4436-944d-02f93abd6c50_480x480.jpg?v=1747023773\" alt=\"Line insulation monitor 1210-6041\" style=\"margin-bottom: 16px; float: right;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cp data-start=\"977\" data-end=\"1055\"\u003e\u003cstrong data-start=\"977\" data-end=\"993\"\u003e1. Part Number :\u003c\/strong\u003e 1210-6041, offering easy identification and order processing.\u003c\/p\u003e\n\u003cp data-start=\"1059\" data-end=\"1144\"\u003e\u003cstrong data-start=\"1059\" data-end=\"1080\"\u003e2. Transformer Type :\u003c\/strong\u003e FL 100, providing efficient insulation monitoring capabilities.\u003c\/p\u003e\n\u003cp data-start=\"1148\" data-end=\"1218\"\u003e\u003cstrong data-start=\"1148\" data-end=\"1168\"\u003e3. Primary Voltage :\u003c\/strong\u003e 115V, suitable for standard voltage applications.\u003c\/p\u003e\n\u003cp data-start=\"1222\" data-end=\"1306\"\u003e\u003cstrong data-start=\"1222\" data-end=\"1244\"\u003e4. Secondary Voltage :\u003c\/strong\u003e 12V, ensuring a suitable voltage level for secondary systems.\u003c\/p\u003e\n\u003cp data-start=\"1310\" data-end=\"1421\"\u003e\u003cstrong data-start=\"1310\" data-end=\"1327\"\u003e5. Power Rating :\u003c\/strong\u003e 5VA for the primary side and 10VA for the secondary side, supporting a range of applications.\u003c\/p\u003e\n\u003cp data-start=\"1425\" data-end=\"1529\"\u003e\u003cstrong data-start=\"1425\" data-end=\"1444\"\u003e6. Current Rating :\u003c\/strong\u003e 0.4A on the primary side, ensuring appropriate current handling for various systems.\u003c\/p\u003e\n\u003cp data-start=\"1533\" data-end=\"1614\"\u003e\u003cstrong data-start=\"1533\" data-end=\"1553\"\u003e7. Frequency Range :\u003c\/strong\u003e 50-60Hz, supporting the standard industrial frequency range.\u003c\/p\u003e\n\u003cp data-start=\"1618\" data-end=\"1735\"\u003e\u003cstrong data-start=\"1618\" data-end=\"1634\"\u003e8. Temperature :\u003c\/strong\u003e Operates at temperatures up to TA40°C, making it suitable for a variety of environmental conditions.\u003c\/p\u003e\n\u003cp data-start=\"1739\" data-end=\"1862\"\u003e\u003cstrong data-start=\"1739\" data-end=\"1767\"\u003e9. Insulation Test Voltage :\u003c\/strong\u003e 5000V, ensuring the device can perform thorough insulation tests in high-voltage environments.\u003c\/p\u003e\n\u003cp data-start=\"1867\" data-end=\"1949\"\u003e\u003cstrong data-start=\"1867\" data-end=\"1887\"\u003e10. Maximum Voltage :\u003c\/strong\u003e EC 10VDC, supporting low voltage control for enhanced safety.\u003c\/p\u003e\n\u003cp data-start=\"1954\" data-end=\"2054\"\u003e\u003cstrong data-start=\"1954\" data-end=\"1979\"\u003e11. Standards Compliance :\u003c\/strong\u003e Meets EN 61558 and IEC 61558 standards for safety and performance.\u003c\/p\u003e\n\u003ch2\u003eApplications:\u003c\/h2\u003e\n\u003cp data-end=\"2195\" data-start=\"2077\"\u003e\u003cstrong data-end=\"2100\" data-start=\"2077\"\u003e1. Electrical Systems :\u003c\/strong\u003e Ideal for use in industrial electrical systems to monitor insulation levels and detect faults.\u003c\/p\u003e\n\u003cp data-end=\"2324\" data-start=\"2199\"\u003e\u003cstrong data-end=\"2222\" data-start=\"2199\"\u003e2. Power Distribution :\u003c\/strong\u003e Used in power distribution networks to ensure the integrity of insulation in transformers and cables.\u003c\/p\u003e\n\u003cp data-end=\"2437\" data-start=\"2328\"\u003e\u003cstrong data-end=\"2347\" data-start=\"2328\"\u003e3. Control Panels :\u003c\/strong\u003e Suitable for use in electrical control panels to monitor insulation and prevent failures.\u003c\/p\u003e\n\u003cp data-end=\"2555\" data-start=\"2441\"\u003e\u003cstrong data-end=\"2458\" data-start=\"2441\"\u003e4. HVAC Systems :\u003c\/strong\u003e Ensures safe operation in HVAC systems, preventing insulation failures in complex wiring setups.\u003c\/p\u003e\n\u003cp data-end=\"2678\" data-start=\"2559\"\u003e\u003cstrong data-end=\"2588\" data-start=\"2559\"\u003e5. Renewable Energy Systems :\u003c\/strong\u003e Provides insulation monitoring in solar and wind energy systems to ensure safe operation.\u003c\/p\u003e\n\u003cp data-end=\"2796\" data-start=\"2682\"\u003e\u003cstrong data-end=\"2701\" data-start=\"2682\"\u003e6. Test Equipment :\u003c\/strong\u003e Ideal for use in testing setups to ensure insulation integrity and prevent electrical hazards.\u003c\/p\u003e\n\u003cp data-end=\"2908\" data-start=\"2800\"\u003e\u003cstrong data-end=\"2818\" data-start=\"2800\"\u003e7. Manufacturing :\u003c\/strong\u003e Used in manufacturing plants to monitor electrical equipment and prevent system failures.\u003c\/p\u003e\n\u003cp data-end=\"3035\" data-start=\"2912\"\u003e\u003cstrong data-end=\"2935\" data-start=\"2912\"\u003e8. Automation Systems :\u003c\/strong\u003e Integrates into industrial automation systems to provide insulation monitoring and fault detection.\u003c\/p\u003e\n\u003cp data-end=\"3168\" data-start=\"3039\"\u003e\u003cstrong data-end=\"3059\" data-start=\"3039\"\u003e9. Heavy Equipment :\u003c\/strong\u003e Used in large machinery and equipment where electrical insulation monitoring is critical for safe operation.\u003c\/p\u003e\n\u003cp data-end=\"3300\" data-start=\"3173\"\u003e\u003cstrong data-end=\"3202\" data-start=\"3173\"\u003e10. Research and Development :\u003c\/strong\u003e Provides a reliable insulation test for new electrical components and systems during development.\u003c\/p\u003e\n\u003cp data-end=\"3300\" data-start=\"3173\"\u003eExplore \u003cstrong\u003e\u003ca href=\"https:\/\/aeliyamarine.com\/collections\/\" title=\"top quality products\"\u003etop quality products\u003c\/a\u003e\u003ca title=\"top quality controller\" href=\"https:\/\/aeliyamarine.com\/collections\/controller\"\u003e\u003c\/a\u003e\u003ca title=\"top quality power supply\" href=\"https:\/\/aeliyamarine.com\/collections\/power-supply\"\u003e\u003c\/a\u003e\u003ca title=\"top quality circuit board\" href=\"https:\/\/aeliyamarine.com\/collections\/pcb\"\u003e\u003c\/a\u003e\u003c\/strong\u003e at Aeliya Marine for precise and efficient flow management in your marine and industrial systems.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":47398985334935,"sku":"65006-539","price":430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0633\/9074\/4727\/files\/20190930_142610_resized.jpg?v=1727254998","url":"https:\/\/aeliyamarine.com\/products\/line-insulation-monitor-1210-6041","provider":"Aeliya Marine","version":"1.0","type":"link"}