{"product_id":"toyo-keiki-is-3-insulation-resistance-monitor-200-230v-50-60hz","title":"Toyo keiki is-3 insulation resistance monitor 200-230v 50\/60hz","description":"\u003cstyle\u003e\n        table {\n            width: Auto;\n            border-collapse: collapse;\n            font-size: 16px;\n        }\n        table, th, td {\n            border: 1px solid black;\n        }\n        th, td {\n            padding: 8px;\n            text-align: left;\n        }\n        th {\n            background-color: #dddddd;\n        }\n    \u003c\/style\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToyo Keiki Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS-3 Insulation Resistance Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 200-230V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 30V, 1A (cos=1) \/ 0.2A (cos=0.4)\u003cbr\u003eAC 100V, 0.5A (cos=1) \/ 0.1A (cos=0.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEJ309804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH-287\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.580 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003eThe Toyo Keiki IS-3 Insulation Resistance Monitor is a reliable, strong tool for measuring insulation resistance of electrical circuits including motors, generators, cables, and other electrical equipment. It's an industrial and commercial-grade tool used to continuously monitor insulation resistance for potential deterioration and avoid downtime or even an electrical accident.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: right;\"\u003e\u003cimg style=\"float: right;\" alt=\"Toyo keiki is-3 insulation resistance monitor 200-230v 50\/60hz\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0633\/9074\/4727\/files\/20200819_160224_resized_1024x_724a7282-f3de-43df-83aa-3691a7c7c446_480x480.webp?v=1734064188\"\u003e\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Voltage Range:\u003c\/strong\u003e This IS-3 operates from 200 to 230V of voltage, making it suitable for a wide variety of applications with standard power supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Frequency Compatibility:\u003c\/strong\u003e It can support both 50Hz and 60Hz power frequencies, which is important for global compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Continuous Monitoring:\u003c\/strong\u003e The device continuously monitors insulation resistance, providing real-time updates and alerts if the resistance drops below a specified threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Insulation Resistance Measurement:\u003c\/strong\u003e It can measure insulation resistance in a range of 1 MΩ to 1000 MΩ or more. This can then detect slight and severe insulation defects.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Alarm Function:\u003c\/strong\u003e The IS-3 has an alarm facility that detects when the insulation resistance drops to a certain threshold level or below the predetermined limits to alert the operator to carry out necessary actions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Easy-to-read display:\u003c\/strong\u003e It has a clear digital or analog display, displaying the measured insulation resistance values and operational status, to make it easy to operate and monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Durable and reliable:\u003c\/strong\u003e The unit is designed for rugged industrial environments with durable enclosures and high resistance to environmental factors such as temperature changes and humidity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. Data Logging (Optional):\u003c\/strong\u003e Some models come with data logging for historical analysis, which can track the condition of the insulation over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e9. User-friendly Interface:\u003c\/strong\u003e The device usually comes with user-friendly interfaces that are simple to calibrate, making it easy to integrate into existing systems.\u003c\/p\u003e\n\u003ch2\u003eApplication:\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Motors \u0026amp; Generators:\u003c\/strong\u003e It is very important for the safe operation of motors and generators to prevent electrical failures due to insulation degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Power Distribution Systems:\u003c\/strong\u003e They are used in substations and electrical grids to monitor the insulation health of transformers and cables, ensuring the reliability of the entire power system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. HVAC Systems:\u003c\/strong\u003e Insulation monitoring in large commercial and industrial HVAC systems protects vital components to avoid system failure and ensure increased safety in operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Renewable Energy Systems:\u003c\/strong\u003e The IS-3 monitors electrical insulation in solar power plants and wind turbines to ensure proper energy output and safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Industrial Machinery:\u003c\/strong\u003e Factories and industrial plants that contain large machinery or equipment need proper insulation integrity in order to avoid electrical faults and enhance safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Buildings \u0026amp; Infrastructure:\u003c\/strong\u003e Guarantees the integrity of electrical installations within buildings, thereby reducing the risk of electrical fires or equipment failure due to poor insulation.\u003c\/p\u003e\n\u003cp\u003eEnsure the safety and reliability of your systems with a \u003ca href=\"https:\/\/aeliyamarine.com\/products\/westronics-sbdg-241-grounding-resistance-monitor\" title=\"Resistance monitor\"\u003e\u003cstrong\u003ehigh-quality resistance monitor\u003c\/strong\u003e\u003c\/a\u003e from Aeliya Marine – your trusted partner in electrical protection.\u003c\/p\u003e","brand":"Toyo Keiki","offers":[{"title":"Default Title","offer_id":47399318159511,"sku":"9740","price":211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0633\/9074\/4727\/files\/20200819_155950_resized__46683.jpg?v=1775192152","url":"https:\/\/aeliyamarine.com\/products\/toyo-keiki-is-3-insulation-resistance-monitor-200-230v-50-60hz","provider":"Aeliya Marine","version":"1.0","type":"link"}