SKU: 65006-539
| Attribute | Details |
|---|---|
| Product | Line Insulation Monitor |
| Part Number | 1210-6041 |
| Transformer Type | FL 100 |
| Primary Voltage | 115V |
| Secondary Voltage | 12V |
| Power Rating | 5VA primary, 10VA secondary |
| Current Rating | 0.4A primary |
| Frequency | 50-60Hz |
| Temperature | TA40°C |
| Insulation Test Voltage | 5000V |
| Maximum Voltage | EC 10VDC |
| Standards | EN 61558, IEC 615580 |
Line Insulation Monitor (Part No: 1210-6041) is a premium monitoring instrument utilized for insulation faults detection within electric systems. With a FL 100 type transformer, it features a primary voltage of 115V and secondary voltage of 12V, which makes it apt for numerous electric configurations. The monitor provides a power rating of 5VA on the primary side and 10VA on the secondary side, with a current rating of 0.4A on the primary. The equipment is designed to run between a frequency of 50-60Hz, and the insulation test voltage has an upper limit of 5000V, which guarantees electrical system safety. Built to function in temperatures up to TA40°C, the Line Insulation Monitor is certified to high levels of safety, such as EN 61558 and IEC 61558.

Key Features:
1. Part Number : 1210-6041, offering easy identification and order processing.
2. Transformer Type : FL 100, providing efficient insulation monitoring capabilities.
3. Primary Voltage : 115V, suitable for standard voltage applications.
4. Secondary Voltage : 12V, ensuring a suitable voltage level for secondary systems.
5. Power Rating : 5VA for the primary side and 10VA for the secondary side, supporting a range of applications.
6. Current Rating : 0.4A on the primary side, ensuring appropriate current handling for various systems.
7. Frequency Range : 50-60Hz, supporting the standard industrial frequency range.
8. Temperature : Operates at temperatures up to TA40°C, making it suitable for a variety of environmental conditions.
9. Insulation Test Voltage : 5000V, ensuring the device can perform thorough insulation tests in high-voltage environments.
10. Maximum Voltage : EC 10VDC, supporting low voltage control for enhanced safety.
11. Standards Compliance : Meets EN 61558 and IEC 61558 standards for safety and performance.
Applications:
1. Electrical Systems : Ideal for use in industrial electrical systems to monitor insulation levels and detect faults.
2. Power Distribution : Used in power distribution networks to ensure the integrity of insulation in transformers and cables.
3. Control Panels : Suitable for use in electrical control panels to monitor insulation and prevent failures.
4. HVAC Systems : Ensures safe operation in HVAC systems, preventing insulation failures in complex wiring setups.
5. Renewable Energy Systems : Provides insulation monitoring in solar and wind energy systems to ensure safe operation.
6. Test Equipment : Ideal for use in testing setups to ensure insulation integrity and prevent electrical hazards.
7. Manufacturing : Used in manufacturing plants to monitor electrical equipment and prevent system failures.
8. Automation Systems : Integrates into industrial automation systems to provide insulation monitoring and fault detection.
9. Heavy Equipment : Used in large machinery and equipment where electrical insulation monitoring is critical for safe operation.
10. Research and Development : Provides a reliable insulation test for new electrical components and systems during development.
Explore top quality products at Aeliya Marine for precise and efficient flow management in your marine and industrial systems.
Hassle-Free Returns & Refunds at Aeliya Marine Tech
We at Aeliya Marine Tech are committed to your satisfaction. If you encounter any issues with your purchase, we want to ensure a smooth and worry-free resolution. Here's what you need to know about our return and refund policy:
Peace of Mind with a 30-Day Warranty:
We offer a generous 30-day warranty on all products from the date of delivery. If your product isn't functioning properly within this timeframe, you can easily request a replacement or refund.
What Can Be Returned?
- Products that are not working as expected (non-functional)
- Products with condition or malfunction issues
- Products with minor cosmetic damages (excluding damage caused during shipping)
Easy Return Process:
- Gather Proof of Purchase: Locate your receipt or invoice with the PI/PO Number, Invoice Number, and Date of Delivery.
- Contact Us: Reach out to our friendly customer support team at sales@aeliyamarine.com or call us at +91 9725218537.
- Return the Product: Securely package the product in its original packaging (if possible) and ship it to the address below:
Receiving Your Refund:
Once we receive the returned product, our team will inspect it thoroughly. Upon approval, your refund will be processed and credited back to your original payment method within a specific timeframe (details available in our Payment Terms).
Missing Refund?
If you haven't received your refund after a reasonable timeframe, check your bank account first. If the refund is still missing, contact your credit card company. Processing delays might occur.
Exchanges for Defective or Damaged Items:
We understand the need for a seamless experience. If you receive a defective or damaged item, we offer a straightforward exchange for the same product. Simply contact us via email at sales@aeliyamarine.com, and we'll guide you through the process.
Warranty Validation:
To facilitate a smooth warranty claim, please share proof of purchase along with relevant documentation like pictures or testing videos specific to your product.
RECENTLY VIEWED PRODUCTS